prd100014 PRD build test report
ProPlayer Gen5 (RK3576) EVT · tested 2026-11-02 · Wilber Zheng
Build
| ROM | pp5-os6-prd100014-proplayer-gen5-evt-ota-prod-e2e-1b889a646.img |
|---|---|
| Commit | 1b889a646 · branch feature/phuoc/ota-trust-ledger-prd100013 |
| OS version | 2644306.100014 · channel prd |
| Board | ProPlayer Gen5 EVT (evt-01), Ethernet + Wi-Fi, 1080p bench monitor |
| Account | testing10 (prod CMS) |
Verdict: passed, and sent to Giada for the 50 pcs batch on 2026-11-02. All functional checks and the playback soak passed. No blocking issue found.
Test results
| Check | Result | |
|---|---|---|
| Flash | Full eMMC write over rockusb with the PRD flash tool. ROM md5 c292ad9f… matches the build record; write rc=0, all 15 partitions written | PASS |
| First boot and pairing | Boots straight to the pairing page with a pairing code; paired to the testing10 account on the prod CMS | PASS |
| Content playback | Playlist with 4K video, YouTube, images and a web page plays and loops; transitions clean | PASS |
| OS UI: Status | OS 2644306.100014, Ethernet up with DHCP address, HDMI 1080p, time zone correct | PASS |
| OS UI: Wi-Fi | Scan lists networks; joined a WPA2 network from the OS UI with the keyboard; Ethernet keeps the default route, both links up | PASS |
| OS UI: Diagnose | Full diagnose run: No Problem Detected | PASS |
| OS UI: Bluetooth | Bluetooth turns on and scans; only supported speakers and remotes are listed by design | PASS |
| Remote reboot from the CMS | 3 reboots: 2 standalone, 1 during the soak. Each back to playback in about 45 s, same content, no re-pair | PASS |
| PRD OTA | Check for update from the OS UI on the prd channel: up to date (prd100014) | PASS |
| Factory reset | Reset from the OS UI: board wipes and returns to the pairing page with a new code; re-paired, content pushed, playback resumes. New device identity, as designed | PASS |
| Playback soak | Screen captured continuously through the soak: every frame changed, no black or frozen screen; a CMS reboot in the middle recovered; device heartbeat live at the end | PASS |
Screenshots
Remarks
- The first automatic OTA check right after boot did not finish (boot quiet window); a manual retry reported up to date.
- The OTA console shows an id conflict for this bench board only, left by its older CMS record; new factory units are not affected.
Previously tested
Earlier testing on this build included:
- Boot
- OS UI and app rendering
- Wi-Fi
- Ethernet
- Bluetooth
- PRD OTA
Status
prd100014 was sent to Giada on 2026-11-02 for the 50 pcs batch.